1. Winding ground fault. In the three-phase winding, one or more insulation damages, causing the iron core and the base in the winding to collide and the current to communicate with the base. Such a fault is called a winding ground fault.

2, failure performance. When the winding is grounded, if the inverter motor casing is not connected to the neutral wire or the protection grounding of the casing is not good, the base will be charged, and the electroscope will be tested. If you touch the base with your hand back, you will be shocked by the electric shock and may cause abnormal noise, vibration and overheating during the operation of the variable frequency speed control motor. In severe cases, the variable frequency speed control motor cannot be started.

3. The influence of winding grounding. After the winding has a ground fault, if the inverter is not properly protected, the chassis will be charged. Although the variable frequency speed control motor can still operate, when the human body touches the base, the current will enter the human body and the earth to form a loop, which is dangerous to human life. When one of the phase windings is grounded, the grounding point forms a loop with the base, which reduces the number of turns of the phase winding, thereby increasing the phase current, resulting in a three-phase current imbalance. When two of the one-phase windings are grounded at the same time, the two groundings of the winding are short-circuited between the core and the base. The more turns of the shorted coil, the greater the phase current increases. If two phases of the two-phase winding are grounded at the same time, it will cause phase-to-phase short circuit, burn the coil, and even make the variable frequency speed control motor unable to start running.

The above is the Frequency control motor stator winding grounding troubleshooting - Database & Sql Blog Articles we have listed for you. You can submit the following form to obtain more industry information we provide for you.

You can visit our website or contact us, and we will provide the latest consultation and solutions

Share to:

Send Inquiry

Home> Industry Information> Frequency control motor stator winding grounding troubleshooting - Database & Sql Blog Articles
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send